Mã lỗi CC180 ... CC186 — Konica-Minolta bizhub C227

Code: CC180 ... CC186

Description:
• CC180: Dynamic link error during starting (LDR) • CC181: Dynamic link error during starting (IBR) • CC182: Dynamic link error during starting (IID) • CC183: Dynamic link error during starting (IPF) • CC184: Dynamic link error during starting (IMY) • CC185: Dynamic link error during starting (SPF) • CC186: Dynamic link error during starting (OAP). A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON.
Causes: MFP board (MFPB)
Remedy: 1. If the malfunction code “C-C172” has occurred, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if “Controller 1,” or “Others” is set for [Image Controller Setting]. If any of these is set, select “Controller 0”. 2. If the malfunction code "C-C180" has occurred, check to install the appropriate loadable device driver for an authentication unit which is installed to the MFP. When the appropriate loadable device driver is not installed, reinstall the appropriate loadable device driver. 3. Replace MFPB. 4. If the above actions do not solve the problem, contact KM. NOTICE • Link to the layout drawings for related parts by each trouble code (S.60. C40A1 - C40A4, C5372, C5601 - C5606, CA051 - CA053, CC151, CC152, CC170 - CC186, CC191 - CC216, CD211 - CD242, CD401 - CD413, CD701 - CD703, CD705, CD706, CE001, CE003 - CE305, CEEE1, CEEE3)

← Xem tất cả mã lỗi Konica-Minolta bizhub C227

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie