Mã lỗi P-22 — Konica-Minolta bizhub C227

Code: P-22

Description: Color regist adjust failure. • The gap between maximum and minimum value of deviations among each color (the values before averaging) is over the predetermined value. • Average deviation exceeds the predetermined value. • In case the final value of the deviation after stabilization exceeds the predetermined value, it is regarded as failure even if the average deviation is within tolerance.
Causes: • IDC sensor/Fr (IDCS/Fr) • IDC sensor/Rr (IDCS/Rr) • MFP board (MFPB)
Remedy: 1. Slide out the imaging unit or drum/developing unit and reinstall it in position. 2. Reinstall or reconnect IDCS/Fr or IDCS/Rr if it is installed or connected improperly. 3. Check the vertical transport guide for installed position and correct as necessary. 4. Replace MFPB.