Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C8102 — Konica-Minolta bizhub C280

Code: C8102

Description: Turn around pressure welding alienation trouble
• During a pressure motion being performed, the reverse roller sensor (PS7) output does not change from H to L. • During a retraction motion being performed, the reverse roller sensor (PS7) output does not change from L to H.
Remedy: 1 Check the connector between M5-DFCB PJ5 for proper connection and correct as necessary. 2 Check the connector between PS7-REYB PJ3 for proper connection and correct as necessary. 3 Check the connector of M5 for proper drive coupling, and correct as necessary. 4 PS7 I/O check, sensor check REYB PJ3-3 (ON) DF-617 L-7. 5 DFCB F9 conduction check. 6 M5 operation check DFCB PJ5-10 to 13 DF-617 I-5. 7 Change M5. 8 DFCB PS2 conduction check. 9 Change FSCB.