Description: LCT communication error
• Due to malfunctioning of the software or other causes, the watchdog timer triggers a reset when time is up.
Remedy: 1 Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. 2 PCCB replacement
Code: C0202
Description: Tray 1 feeder up/down abnormality
• The paper feed tray 1 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Remedy: 1 Check the connector between M12-PRCB CN18 for proper connection and correct as necessary. 2 Check the connector of M12 for proper drive coupling and correct as necessary. 3 Check the connector between PS25-relay CN106-PRCB CN21 for proper connection and correct as necessary. 4 PS25 I/O check, sensor check. 5 M12 operation check. 6 Change M12. 7 PRCB ICP7 conduction check. 8 Change PRCB.
Code: C0204
Description: Tray 2 feeder up/down abnormality
• The paper feed tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Remedy: 1 Check the connector between M13-PRCB CN18 for proper connection and correct as necessary. 2 Check the connector of M13 for proper drive coupling and correct as necessary. 3 Check the connector between PS22-relay CN113-PRCB CN22 for proper connection and correct as necessary. 4 PS22 I/O check, sensor check. 5 M13 operation check. 6 Change M13. 7 PRCB ICP7 conduction check. 8 Change PRCB.
Code: C0206
Description: Tray3 lift-up failure
• The lift-up upper sensor is not blocked even
Remedy: 1 Check the connector between M124-PCCB CN4 for proper connection and correct as necessary. 2 Check the connector between M125-PCCB CN8 for proper connection and correct as necessary. 3 Check the connector between PS114- PCCB CN6 for proper connection and correct as necessary. 4 Check the connector between PS123- PCCB CN10 for proper connection and correct as necessary. 5 Check the connector of each motor for proper drive coupling, and correct as necessary. 6 PS114 I/O check, sensor check. 7 PS123 I/O check, sensor check. 8 M124 operation check. 9 M125 operation check. 10 Change PRCB. 11 Change MFPB.
Code: C0208
Description: Tray4 lift-up failure
After the set period of time has elapsed after the paper lift-up operation for the drawer began.
Remedy: 1 Check the connector between M124-PCCB CN4 for proper connection and correct as necessary. 2 Check the connector between M125-PCCB CN8 for proper connection and correct as necessary. 3 Check the connector between PS114- PCCB CN6 for proper connection and correct as necessary. 4 Check the connector between PS123- PCCB CN10 for proper connection and correct as necessary. 5 Check the connector of each motor for proper drive coupling, and correct as necessary. 6 PS114 I/O check, sensor check. 7 PS123 I/O check, sensor check. 8 M124 operation check. 9 M125 operation check. 10 Change PRCB. 11 Change MFPB.
Code: C0209
Description: LCT elevator motor failure
• The elevator motor pulse sensor (PS10) cannot detect both edges of H/L even after the set period of time has elapsed while the elevator motor (M5) is turning backward/forward (raise/lower).
Remedy: 1 Check the connector between M5-REYB CN2 for proper connection and correct as necessary. 2 Check the connector between PS10-REYB CN2 for proper connection and correct as necessary. 3 Check the connector of each motor for proper drive coupling, and correct as necessary. 4 PS10 I/O check, sensor check. 5 M5 operation check. 6 Change REYB. 7 Change PCCB.
Code: C0210
Description: LCT lift failure
• The lift-up upper limit sensor (PS4) is not blocked even after the set period of time has elapsed after the paper lift-up operation began. • The lift-up upper limit sensor (PS4) is not blocked even after the set pulse is detected by the elevator motor pulse sensor (PS10) after the paper lift-up operation began. • The lift-up lower sensor (PS13) is not unblocked even after the set pulse is detected by the elevator motor pulse sensor (PS10) after the paper lift-up operation began. • The lift-up upper limit sensor (PS4) is not blocked even after the set period of time has elapsed after the paper lift-up operating. • The lift-up lower limit sensor (PS13) is not blocked even after the set period of time has elapsed after the paper lift-down operation began. • The lift-up lower limit sensor (PS13) is not blocked even after the set pulse is detected by the elevator motor pulse sensor (PS10) after the paper lift-down operation began. • The lift-up upper limit sensor (PS4) is not unblocked even after the set pulse is detected by the elevator motor pulse sensor (PS10) after the paper lift-down operation began. • The lower limit over run sensor (PS7) is blocked while the paper lift-down operating.
Remedy: 1 Check the connector between PS4-PCCB CN5 for proper connection and correct as necessary. 2 Check the connector between PS13-PCCB CN2 for proper connection and correct as necessary. 3 Check the connector between PS10-PCCB CN2 for proper connection and correct as necessary. 4 Check the connector between PS7-PCCB CN2 for proper connection and correct as necessary. 5 PS4 I/O check, sensor check. 6 PS13 I/O check, sensor check. 7 PS10 I/O check, sensor check. 8 PS7 I/O check, sensor check. 9 Change PCCB.
Code: C0211
Description: Manual feed up/down abnormality
• Paper does not unblock the manual lift-up position sensor even after the transport motor rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. • The manual lift-up position sensor is not blocked even after the transport motor rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
Remedy: 1 Check the connector between M1-PRCB CN14 for proper connection and correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as necessary. 3 Check the connector between PS26-relay CN93-PRCB CN19 for proper connection and correct as necessary. 4 Check the connector between SD1-relay CN99-relay CN93-PRCB CN19 for proper connection and correct as necessary. 5 PS26 I/O check, sensor check. 6 SD1 operation check. 7 M1 operation check. 8 Change M1. 9 PRCB ICP5 conduction check. 10 Change PRCB.