Description: Glass cleaning mechanism trouble
• The glass cleaning sensor (PS21) is not turned ON after the set period of time has elapsed after the glass cleaning motor (M9) is turned ON.
Remedy: 1 Check the connector between M9-DFCB PJ17 for proper connection and correct as necessary. 2 Check the connector between PS21-DFCB PJ17 for proper connection and correct as necessary. 3 Check the connector of M9 for proper drive coupling, and correct as necessary. 4 PS21 I/O check, sensor check DFCB PJ17-7 (ON) DF-617 I-3. 5 M9 operation check DFCB PJ17-1 to 4 DF-617 I-3. 6 Change M9. 7 Change DFCB.