Mã lỗi C3101 — Konica-Minolta bizhub C300

Code: C3101

Description: Fusing pressure roller separation failure
• With the pressure roller being retracted, the pulse of the encoder sensor does not change even after the specified period of time has passed after the fusing pressure roller pressure/retraction motor started rotating. • With the pressure roller being pressed, the encoder pulse sensor does not change even after the specified period of time has passed after the fusing pressure roller pressure/retraction motor started rotating. • With the pressure roller being pressed, the fusing roller retraction sensor did not turn ON (pressed) even after the encoder pulse sensor counted up the specified number of pulse after the fusing pressure roller pressure/retraction motor started rotating.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 PC23 I/O check, sensor check MFPB CNDM4-12 (ON) K-8 3 PC23 operation check. 4 M24 operation check MFPB CNDM4-13 to 14 K-8. 5 Change fusing unit. 6 Change MFPB.