Description: LCT vertical transport motor malfunction
Remedy:
Code: C0204
Description: Tray 2 elevator failure
• The lift-up sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Remedy: 1 Check the M3-PC connector for proper connection and correct as necessary. 2 Check the connector of M3-PC for proper drive coupling and correct as necessary. 3 PC7-PC I/O check, sensor check PCCB PJ6PCCB-3 (ON) S-24. 4 M3-PC operation check PCCB PJ4PCCB-4 to 5 M-27. 5 Change PCCB
Code: C0206
Description: Tray 3 elevator failure
Remedy:
Code: C0208
Description: Tray 4 elevator failure
Remedy:
Code: C0209
Description: LCT elevator motor malfunction (elevator malfunction)
Remedy:
Code: C0210
Description: LCT ascent motion failure
Remedy:
Code: C0211
Description: Manual tray rise descent error
• The bypass lift-up sensor is not blocked even when the tray 2 vertical transport motor has turned for a given number of pulses after the sequence to move the paper lifting plate from the standby position to the feed position was started. • The bypass lift-up sensor is not unblocked even when the tray 2 vertical transport motor has turned for a given number of pulses after the sequence to move the paper lifting plate from the feed position to the standby position was started.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as necessary. 3 PC14 I/O check, sensor check MFPB CNTRY1-10 (ON) C-9. 4 M1 operation check MFPB CNDM1-5 (REM) MFPB CNDM1-8 (LOCK) L-2. 5 Change MFPB.