Code: 2A24
Description: Toner cartridge/K new release failure
The status with the new cartridge is not cleared after the new toner cartridge is set.
The status with the new cartridge is not cleared after the new toner cartridge is set.
Causes: • Toner cartridge/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Check the connector between toner cartridge-relay CN79-EXCB CN4 for proper connection and correct as necessary. - - 2 Clean the connection between the toner cartridge and the machine if dirty. - - 3 Reinstall the toner cartridge 4 Check the harness for proper connection and correct as necessary. - - 5 Check the connector between EXCB CN2-PRCB CN11 for proper connection and correct as necessary. - - 6 Replace the toner cartridge - - 7 Replace PRCB