Description: Tray 2 PC transport motor malfunction The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • PC transport motor (M51) • Printer control board (PRCB) • PC control board (PCCB)
Remedy: 1 Check the connector between M51-PCCB PJ3 for proper connection and correct as necessary. - - 2 Check the connector between PCCB PJ1-relay CN153-PRCB CN7 for proper connection and correct as necessary. - - 3 Check the connector of M51 for proper drive coupling and correct as necessary. - - 4 M51 operation check PCCB PJ3-4 to 8 2-L 5 Replace M51 - - 6 Replace PCCB - - 7 Replace PRCB
Description: Tray 3 PC transport motor malfunction The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • PC transport motor (M51) • Printer control board (PRCB) • PC control board (PCCB)
Remedy: 1 Check the connector between M51-PCCB PJ3 for proper connection and correct as necessary. - - 2 Check the connector between PCCB PJ1-relay CN154-PCCB PJ2 for proper connection and correct as necessary. - - 3 Check the connector between PCCB PJ1-relay CN153-PRCB CN7 for proper connection and correct as necessary. - - 4 Check the connector of M51 for proper drive coupling and correct as necessary. - - 5 M51 operation check PCCB PJ3-4 to 8 2-L 6 Replace M51 - - 7 Replace PCCB - - 8 Replace PRCB
Description: 1st transfer pressure/retraction malfunction • The 1st transfer pressure sensor (PS9) does not change its state from one corresponding to the retracted position to the pressed position within a predetermined period of time after the 1st transfer pressure solenoid (SD1) has been energized. • The 1st transfer pressure sensor (PS9) does not change its state from one corresponding to the pressed position to the retracted position within a predetermined period of time after the 1st transfer pressure solenoid (SD1) has been energized.
Causes: • Main motor (M1) • 1st transfer pressure sensor (PS9) • 1st transfer pressure solenoid (SD1) • Printer control board (PRCB)
Remedy: 1 Check the connector between M1-PRCB CN9 for proper connection and correct as necessary. - - 2 Check the connector of M1 for proper drive coupling and correct as necessary. - - 3 Check the connector between PS9- PRCB CN12 for proper connection and correct as necessary. - - 4 Check the connector between SD1-relay CN85-PRCB CN12 for proper connection and correct as necessary. - - 5 PS9 I/O check, sensor check PRCB CN12-3 (ON) 15-C to D 6 SD1 operation check PRCB CN12-12 (REM) 15-E 7 M1 operation check PRCB CN9-3 to 6 15-B 8 Replace M1 - - 9 PRCB F4 conduction check - - 10 Replace PRCB
Description: Developing motor malfunction • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • The motor does not reach its steady rotating state even after the lapse of a predetermined period of time after it has been started.
Causes: • Developing motor (M3) • Printer control board (PRCB)
Remedy: 1 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. - - 2 Check the M3 connector for proper drive coupling and correct as necessary. - - 3 M3 operation check PRCB CN8-3 to 6 7-J
Description: Color PC motor malfunction • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • The motor does not reach its steady rotating state even after the lapse of a predetermined period of time after it has been started.
Causes: • Color PC motor (M4) • Printer control board (PRCB)
Remedy: 1 Check the connector between M4-PRCB CN8 for proper connection and correct as necessary. - - 2 Check the M4 connector for proper drive coupling and correct as necessary. - - 3 M4 operation check PRCB CN8-10 to 13 7-J 4 Replace M4 - - 5 PRCB F7 conduction check - - 6 Replace PRCB
Description: Toner suction fan motor malfunction The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Toner suction fan motor (FM3) • Printer control board (PRCB)
Remedy: 1 Check the connectors between FM3-relay CN301- PRCB CN3 for proper connection, and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 FM3 operation check PRCB CN3-1 (OUT) PRCB CN3-3 (LOCK) 7-K 4 Replace FM3 - - 5 PRCB F2 conduction check - - 6 Replace PRCB
Description: Imaging unit/C new article release The status with the new unit is not cleared after the new imaging unit is set.
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB
Description: Imaging unit/M new article release The status with the new unit is not cleared after the new imaging unit is set.
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.