Mã lỗi 3821 — Konica-Minolta bizhub C3350

Code: 3821

Description: Fusing abnormally low temperature (Main of the heating roller)
The fusing temperature sensor/1 (TEM1: main of the heating side) continues to detect a temperature lower than a predetermined one for a predetermined period of time after warm-up is complete.
Causes: • Fusing unit • Fusing temperature sensor/1 (TEM1: main of the heating side) • DC power supply (DCPS) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). - - 2 Check the open/close operation of the upper right door. - - 3 Check the fusing unit -PRCB CN15, DCPS CN2 for proper connection and correct or change as necessary. - - 4 Replace the fusing unit - - 5 Replace DCPS - - 6 Replace PRCB