Code: 3926
Description: Fusing sensor wire breaks abnormality (Middle of the heating roller)
After a predetermined period of time after the warm-up stage is started, the fusing temperature sensor/1 (TEM1: center of the heating side) voltage does not decrease by predetermined steps (temperature rise) within a predetermined time.
After a predetermined period of time after the warm-up stage is started, the fusing temperature sensor/1 (TEM1: center of the heating side) voltage does not decrease by predetermined steps (temperature rise) within a predetermined time.
Causes: • Fusing unit • Fusing temperature sensor/1 (TEM1: center of the heating side) • DC power supply (DCPS) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). - - 2 Check the open/close operation of the upper right door. - - 3 Check the fusing unit-PRCB CN15, DCPS CN2 for proper connection and correct or change as necessary. - - 4 Replace the fusing unit - - 5 Replace DCPS - - 6 Replace PRCB