Code: 5701
Description: Power supply malfunction
A condition is detected in which no power is being supplied to the printer control board (PRCB).
A condition is detected in which no power is being supplied to the printer control board (PRCB).
Causes: • PH unit • Toner supply motor/YM (M5) • Toner supply motor/CK (M6) • Front door switch (SW2) • Right door switch (SW3) • DC power supply (DCPS) • Printer control board (PRCB)
Remedy: 1 Check the connector between SW2, SW3-DCPS CN10 for proper connection and correct as necessary. - - 2 Check the connector between M5, M6-PRCB CN22 for proper connection and correct as necessary. - - 3 Check the connector between PH unit-relay CN73- PRCB CN5 for proper connection and correct as necessary. - - 4 M5, M6 operation check PRCB CN22-1 to 4 (M5) PRCB CN22-5 to 8 (M6) 7-I 7-K 5 SW2, SW3 operation check DCPS CN10-1 to 3 1-F 6 Replace the PH unit - - 7 Replace DCPS - - 8 PRCB F5, F10 conduction check - - 9 Replace PRCB