Code: 6751
Description: CCD clamp/gain adjustment failure
During the CCD gain adjustment, a condition in which the peak value of the output data is equal to, or less than, 64 occurs three consecutive times during retries.
During the CCD gain adjustment, a condition in which the peak value of the output data is equal to, or less than, 64 occurs three consecutive times during retries.
Causes: • Scanner unit • MFP board (MFPB)
Remedy: 1 Check the connector between scanner unit-MFPB CN102, CN103 for proper connection and correct as necessary. - - 2 Check for possible extraneous light and correct as necessary. - - 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty. - - 4 Correct reflective mirror of the scanner if faulty, or change scanner mirror. - - 5 Replace scanner unit - - 6 Replace MFPB