Code: C0510
Description: Fuser temperature low
• The temperature detected by the Thermistor remains lower than the set temperature continuously for a predetermined period of time while the fusing temperature control is being provided. (The set temperatures are as follows: 140 °C during a print mode at 600 dpi; 70 °C during the standby mode.)
• The temperature detected by the Thermistor remains lower than the set temperature continuously for a predetermined period of time while the fusing temperature control is being provided. (The set temperatures are as follows: 140 °C during a print mode at 600 dpi; 70 °C during the standby mode.)
Remedy: 1 Replace Thermistor (TH1). 2 Replace Fusing Unit. 3 Replace Controller/Mechanical Control Board (PWB-P). 4 Replace Power Unit (PU1).