Description: 43.41z Cyan bottle TMC error. 43.42z Magenta bottle TMC error. 43.43z Yellow bottle TMC error. z codes: • Y— First error, recoverable • Z— Second error, non-recoverable
Remedy: Step 1 a Enter the Diagnostics menu, and then navigate to: Printer diagnostics & adjustments > Sensor tests b Find the sensor (Toner meter). Does the sensor status change while toggling the sensor? Go to step 2. Go to step 3. Step 2 Replace the toner cartridge. Does the problem remain? Go to step 3. The problem is solved. Step 3 Replace the TMC card. See “TMC card removal”. Does the problem remain? Contact the next level of support. The problem is solved.