Description: 666.83 The motor (tray 2 pass-through) stalled. 667.83 The motor (tray 3 pass-through) stalled. 668.83 The motor (tray 4 pass-through) stalled.
Remedy: Step 1 a Enter the Diagnostics menu, and then navigate to: Additional input tray diagnostics > Motor tests > Pass.through (tray [x]) b Touch Start. Does the motor run? Go to step 4. Go to step 2. Step 2 Check the motor cable for proper connection, and reseat if necessary. Does the problem remain? Go to step 3. The problem is solved. Step 3 Replace the motor. See gMotor (550-sheet tray pass.through) removalh. Does the problem remain? Go to step 4. The problem is solved. Step 4 Check the motor for noise. Does the motor sound abnormal or do the gears make a grinding sound? Contact the next level of suppoStep 6 Replace the controller board. See “550-sheet tray controller board assembly removal”. Does the problem remain? Contact the next level of support. The problem is solved.rt. Go to step 5. Step 5 Perform a print job. Does the problem remain? Go to step 6. The problem is solved.