Code: 920.22
Description: POST Error
Fuser bubble sensor is not connected.
Fuser bubble sensor is not connected.
Remedy: 1 Is the bubble sensor flag damaged? Replace the fuser. See “Fuser removal”. Go to step 2.
2 Remove the rear frame cover. See “Rear frame cover removal”. Check the fuser DC cable in connector JFUSER1 (A) for proper connection to the system board, pinch points, and any other damage to the cable or connector. Is the cable damaged? Replace the fuser DC cable. See “Fuser DC cable removal”. Go to step 3.
3 Place a voltmeter between the fuser DC autoconnect, pin 3 and ground (pin 6). Does the voltage meter read +5 V dc? Go to step 5. Go to step 4.
5 1. Replace the fuser. 2. Bring the printer up in Diagnostics Menu (turn off the printer, press and hold and . and turn on the printer). 3. Select SENSOR TESTS, and press Select( ). 4. Select Dynamic Sensors, and press Select( ). 5. Select Bubble, and press Select( ). 6. Open the front door. 7. Activate the bubble sensor. Did the bubble sensor change from Open to Closed? Problem resolved. Replace the system board. See “System board removal”.
2 Remove the rear frame cover. See “Rear frame cover removal”. Check the fuser DC cable in connector JFUSER1 (A) for proper connection to the system board, pinch points, and any other damage to the cable or connector. Is the cable damaged? Replace the fuser DC cable. See “Fuser DC cable removal”. Go to step 3.
3 Place a voltmeter between the fuser DC autoconnect, pin 3 and ground (pin 6). Does the voltage meter read +5 V dc? Go to step 5. Go to step 4.
5 1. Replace the fuser. 2. Bring the printer up in Diagnostics Menu (turn off the printer, press and hold and . and turn on the printer). 3. Select SENSOR TESTS, and press Select( ). 4. Select Dynamic Sensors, and press Select( ). 5. Select Bubble, and press Select( ). 6. Open the front door. 7. Activate the bubble sensor. Did the bubble sensor change from Open to Closed? Problem resolved. Replace the system board. See “System board removal”.