Code: 4200
Description: BD stability error
The BD signal is not detected for 1000 ms after processing the compulsion lighting. At the interrupt in VSYNC, the BD error is detected continuously for 10 times in 400 ms intervals.
The BD signal is not detected for 1000 ms after processing the compulsion lighting. At the interrupt in VSYNC, the BD error is detected continuously for 10 times in 400 ms intervals.
Causes: Defective connector cable or poor contact in the connector. Defective APC PWB. Defective main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Laser scanner unit (YC1) and main PWB (YC5)
Defective APC PWB. Replace the laser scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.
Defective APC PWB. Replace the laser scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.