Code: 6020
Description: Abnormally high fuser thermistor M temperature
30/31 ppm printer (EUR/USA model): The temperature of the fuser thermistor M detects 250°C/482°F or more continuously for 3 s. 35/37 and 45/47 ppm printers (EUR/USA model): The temperature of the fuser thermistor M detects 240°C/464°F or more continuously for 3 s
30/31 ppm printer (EUR/USA model): The temperature of the fuser thermistor M detects 250°C/482°F or more continuously for 3 s. 35/37 and 45/47 ppm printers (EUR/USA model): The temperature of the fuser thermistor M detects 240°C/464°F or more continuously for 3 s
Causes: Shorted fuser thermistor M. Defective engine PWB.
Remedy: Shorted fuser thermistor M. Measure the resistance. If it is 0 W, replace the fuser thermistor M.
Defective engine PWB. Replace the engine PWB.
Defective engine PWB. Replace the engine PWB.