Remedy: Black printhead lost Hsync Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J12 and J13 on the system board. Go to “System board” on page 5-8. If the cables are connected correctly to the system board and to the printhead assembly, go to “Printhead diagnostics”. Note: Do not adjust or replace any printhead before performing checks in “Printhead diagnostics”