Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Toshiba e-Studio 200CP

Code: 100 ... 104

Description: ITU Error
Remedy: ITU stall. Invalid ITU memory - Replace “ITU assembly”. ITU shorted thermistor - Replace “ITU assembly”. Memory load error - Replace “ITU assembly”. ITU belt tracking - Go to “104 ITU Error”

Code: 106

Description: Printhead Error
Remedy: Cyan printhead lost Hsync Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J8, and J9 on the system board. If the cables are connected correctly to the system board and to the printhead assembly, go to “Printhead diagnostics”. Note: Do not adjust or replace any printhead before performing checks in “Printhead diagnostics”

Code: 107

Description: Printhead Error
Remedy: Magenta printhead lost Hsync Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J11 and J12 on the system board. Go to “System board”. If the cables are connected correctly to the system board and to the printhead assembly, go to “Printhead diagnostics”.

Code: 108

Description: Printhead Error
Remedy: Yellow printhead lost Hsync Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J7 and J8 on the system board. Go to “System board” If the cables are connected correctly to the system board and to the printhead assembly, replace the “Printhead diagnostics”. Note: Do not adjust or replace any printhead before performing checks in “Printhead diagnostics”

Code: 109

Description: Printhead Error
Remedy: Black printhead lost Hsync Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J12 and J13 on the system board. Go to “System board” on page 5-8. If the cables are connected correctly to the system board and to the printhead assembly, go to “Printhead diagnostics”. Note: Do not adjust or replace any printhead before performing checks in “Printhead diagnostics”

Code: 110

Description: Printhead Error
Remedy: No first Hysnc - cyan Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J8 and J9 on the system board. Go to “System board” on page 5-8. If the cables are connected correctly to the system board and to the printhead assembly, replace the “Printhead diagnostics”. Note: Do not adjust or replace any printhead before performing checks in “Printhead diagnostics”

Code: 111

Description: Printhead Error
Remedy: No first Hysnc - magenta Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J11 and J12 on the system board. Go to “System board”. If the cables are connected correctly to the system board and to the printhead assembly, go to “Printhead diagnostics”

Code: 112

Description: Printhead Error
Remedy: No first Hysnc - yellow Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J7 and J8 on the system board. Go to “System board”. If the cables are connected correctly to the system board and to the printhead assembly, go to “Printhead diagnostics”. Note: Do not adjust or replace any printhead before performing checks in “Printhead diagnostics”