Các lỗi thường gặp

Code :
  • Code: 100 ... 104
  • Description: ITU Error
  • Remedy: ITU stall. Invalid ITU memory - Replace “ITU assembly”. ITU shorted thermistor - Replace “ITU assembly”. Memory load error - Replace “ITU assembly”. ITU belt tracking - Go to “104 ITU Error”
  • Code: 106
  • Description: Printhead Error
  • Remedy: Cyan printhead lost Hsync Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J8, and J9 on the system board. If the cables are connected correctly to the system board and to the printhead assembly, go to “Printhead diagnostics”. Note: Do not adjust or replace any printhead before performing checks in “Printhead diagnostics”
  • Code: 107
  • Description: Printhead Error
  • Remedy: Magenta printhead lost Hsync Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J11 and J12 on the system board. Go to “System board”. If the cables are connected correctly to the system board and to the printhead assembly, go to “Printhead diagnostics”.
  • Code: 108
  • Description: Printhead Error
  • Remedy: Yellow printhead lost Hsync Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J7 and J8 on the system board. Go to “System board” If the cables are connected correctly to the system board and to the printhead assembly, replace the “Printhead diagnostics”. Note: Do not adjust or replace any printhead before performing checks in “Printhead diagnostics”
  • Code: 109
  • Description: Printhead Error
  • Remedy: Black printhead lost Hsync Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J12 and J13 on the system board. Go to “System board” on page 5-8. If the cables are connected correctly to the system board and to the printhead assembly, go to “Printhead diagnostics”. Note: Do not adjust or replace any printhead before performing checks in “Printhead diagnostics”
  • Code: 110
  • Description: Printhead Error
  • Remedy: No first Hysnc - cyan Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J8 and J9 on the system board. Go to “System board” on page 5-8. If the cables are connected correctly to the system board and to the printhead assembly, replace the “Printhead diagnostics”. Note: Do not adjust or replace any printhead before performing checks in “Printhead diagnostics”
  • Code: 111
  • Description: Printhead Error
  • Remedy: No first Hysnc - magenta Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J11 and J12 on the system board. Go to “System board”. If the cables are connected correctly to the system board and to the printhead assembly, go to “Printhead diagnostics”
  • Code: 112
  • Description: Printhead Error
  • Remedy: No first Hysnc - yellow Check for the correct installation of all the cables to the system board assembly and to the printhead assembly; J7 and J8 on the system board. Go to “System board”. If the cables are connected correctly to the system board and to the printhead assembly, go to “Printhead diagnostics”. Note: Do not adjust or replace any printhead before performing checks in “Printhead diagnostics”
 1 2 3 4 >  Last ›