Remedy: 1 Is the top access door completely closed? Go to step 2. Close the top access door. 2 Open the top access door, and slowly close it. You should hear the top access door 24 V interlock switch closing when the door almost shuts. If you do not, check the switch for damage. Is the switch damaged? Replace the top access door 24 V interlock switch. Go to step 3. 3 Close the top access door. Turn printer power on, and check for 24 V dc between JCVR1 pin 1 (red wire) and ground. Note: The ground lead of the voltmeter can be placed on the metal frame to obtain ground. Is voltage present? Replace the top access door 24 V interlock switch. Go to step 4. 4 Replace the bump aligner motor. Does the error clear? Problem solved. Replace the system card.