Description: Waste toner motor locking error ("Waste toner box replacement"): "Waste toner box replacement" appears when either CD70 or CD71 error occurs. The error code CD72 is noted on the error history and logs.
Causes: Waste toner transport motor (M31) Auger lock detection sensor (S42) LGC board
Remedy: 1 Is the waste toner transport motor (M31) rotating? (Perform the output check: 03-415) Yes 4 No 2 2 Waste toner transport motor (M31) • Connector and relay connector check • Check if there is any damage or abnormality in the gears on the driving cascade of the waste toner transport motor. 3 LGC board • Connector check (CN342) • Board check 4 Is the auger lock detection sensor (S42) operating normally? (Perform output check: 03-[FAX] ON/[2]/[G]) * To judge an error, check if the sensor detects each status of normal display and highlighted display. Yes 6 No 5 5 Auger lock detection sensor (S42) Connector and relay connector check 6 LGC board • Connector check (CN359) • Board check