Code: E400
Description: Jam access cover open jam: The jam access cover has opened during printing.
Causes: Switching regulator LGC board Transfer cover switch
Remedy: Switching regulator • Is the voltage of 24V being supplied from the power supply unit? (Perform the input check: 03-[FAX] ON[2]/[B]) • Connector check (CN345, CN361) • Fuse check (F201, F202, F203) LGC board • Board check • Connector check (CN345, CN361) • Harness check Transfer cover switch • Switch check (Perform the input check: 03-[FAX] ON[3]/[D]) • Connector check (CN338) • Harness check