Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CEC5 — Toshiba e-Studio 6570C

Code: CEC5

Description: Incorrect cam position alarm during 2nd transfer
Causes: Actuator in the TRU Sensors in the TRU
Remedy: 1 2nd transfer contact/release cam unit gear Check that it is not damaged. 2 Actuator in the TRU • Check that it is installed properly. • Check that it is not damaged. 3 Sensors in the TRU • Check that they are installed properly. • Check that the cam is not damaged. 4 If any abnormality on a part is detected and the part is replaced, the 2nd transfer pressure reduction is enabled by changing the value of the setting codes as follows: 08-4663: 0 to 10: Pressure reduction disabled1: Pressure reduction enabled 08-4664: 3 to 0Resetting incorrect cam position error count Notes: Change the value of the following codes to disable the pressure reduction: 08-4663: 1 to 0 0: Pressure reduction disabled 1: Pressure reduction enabled 08-4664: 0, 1 or 2 to 3 Resetting incorrect cam position error count

← Xem tất cả mã lỗi Toshiba e-Studio 6570C

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie