Code: EA10
Description: Paper transport delay jam: The paper which has passed the relay transport path does not reach the inlet sensor. [MJ-1103/1104]
Causes: Feeding sensor (S22) Transport path switching solenoid (SOL5) Entrance motor (M1) Interface PC board (I/F) Finisher control PC board (FIN)
Remedy: Finisher Check if there is any paper in the finisher or on the transport path of the equipment and remove it if there is. Feeding sensor (S22) Check if there is a disconnection of the connector, incorrect installation or breakage of the feeding sensor (S22). If there is, reinstall the sensor correctly or replace it. Transport path switching solenoid (SOL5) Check that the gap between the transfer guide surface and the upper surface of the flapper tip is in the acceptable range according to the status of the transport path switching solenoid (SOL5) (solenoid OFF: 1.5 to 2.1 mm, solenoid ON: 2.3 to 2.9 mm). If it is not, adjust it. Entrance motor (M1) Check the harness between the entrance motor (M1) and the finisher controller board (CN26). If there is any abnormality, correct it. Interface PC board (I/F) Check the harness between the transport path switching solenoid (SOL5) and the interface PC board (CN6), If there is any abnormality, correct it. • Board check • Connector check (CN5, CN6, CN7) • Harness check Finisher control PC board (FIN) • Board check • Connector check (CN25, CN27) • Board check