Mã lỗi E 22 — Riso GR1750

Code: E 22

Description: Master Mis-Feed
Displayed after the master has been loaded onto the Drum in the master making or confidential process:
1) If the Master positioning sensor has not detected master material within 787 pulses (536 pulses in confidential process) after the Loading pulse motor started following the master cutting operation. Displayed to interrupt the machine operation when the Master loading button was pressed: 1) If the Master positioning sensor has not detected master material within 1260 pulses after the Loading pulse motor was turned on.
2) If the Master positioning sensor has not detected master material within 787 pulses after the Loading pulse motor was turned on following the operation of the Cutter motor and the cut master material is removed.