Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 314 S06 — Riso HC5500

Code: 314 S06

Description: Ink heating timeout When the temperature of ink in the distributor meets the following conditions after being heated for a set time: 1) & either 2), 3) 4), 5), 6) or 7) 1) The temperature is less than 15 °C. 2) It takes more than 360 seconds to raise the temperature by 1 °C after the heater has been powered on. 3) It takes more than 600 seconds to raise the temperature by 4 °C after the heater has been powered on. 4) It takes more than 750 seconds to raise the temperature by 7 °C after the heater has been powered on. 5) It takes more than 900 seconds to raise the temperature by 10 °C after the heater has been powered on. 6) It takes more than 1,320 seconds to raise the temperature by 13 °C after the heater has been powered on. 7) A temperature of less than 15 °C holds for more than 1,800 seconds. * Head identification information (K, C, M, Y) is added after the error point.

← Xem tất cả mã lỗi Riso HC5500

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin