Description: Power supply remote signal not connected The control signal cable for the ON/OFF control of the 24/38-VDC output is disconnected. The signal wire grounded inside the power supply unit has been pulled up by the IP PCB to detect the level.
Description: 38-VDC power supply voltage error A voltage drop is detected when a voltage drop is sensed by the IP PCB based on the signal resulting from dividing the 38-VDC resistance inside the power supply unit. The detection level is approximately 18 VDC. Voltage polling is conducted at 100-ms intervals by the IP-CPU. An error is detected when a voltage drop is sensed 10 times in succession (approx. 1 sec). No detection is performed when the interlock SW is open.
Description: 24-VDC power supply voltage error A voltage drop is detected when a voltage drop is sensed by the IP PCB based on the signal resulting from dividing the 24-VDC resistance inside the power supply unit. The detection level is approximately 11 VDC. Voltage polling is conducted at 100-ms intervals by the IP-CPU. An error is detected when a voltage drop is sensed 10 times in succession (approx. 1 sec). No detection is performed when the interlock SW is open.
Description: 3.3-VDC power supply voltage error A voltage drop is detected when a voltage drop is sensed in the 3.3-VDC power supply on the MIP side of the IP PCB. Voltage polling is conducted at 100-ms intervals by the IP-CPU. An error is detected when a voltage drop is sensed 10 times in succession (approx. 1 sec).
Description: 1.8-VDC power supply voltage error A voltage drop is detected when a voltage drop is sensed in the 1.8-VDC power supply on the MIP side of the IP PCB. Voltage polling is conducted at 100-ms intervals by the IP-CPU. An error is detected when a voltage drop is sensed 10 times in succession (approx. 1 sec).
Description: Control panel not connected The absence of the control panel unit to be connected to the MC PCB is detected. Since this configuration lacks this panel, this error indication will not be issued under normal operating circumstances.