Code: F0-34
Description: Finisher punch motor section abnormality (FCM102). The punching operation of the punch unit in the finisher is abnormal.
Causes: Motor lock, control PWB trouble, disconnection of harness or connector, HP sensor breakdown.
Remedy: Use SIM3-3 to check the operation of the punch motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.