Code: L4-30
Description: MFP cooling fan / HDD cooling fan trouble. The motor lock signal is detected during rotation of the MFP cooling fan or HDD cooling fan.
Causes: Fan motor trouble, controller PWB trouble, SCNMother PWB trouble, fan motor/SCN-Mother PWB harness connection trouble, controller PWB/SCNMother PWB connection trouble, control circuit trouble
Remedy: Use SIM06-02 to check the operation of the fan motor. Check the controller PWB, the SCN-Mother PWB, and the harness and the connector between the fan motor and the SCN-Mother PWB.