Mã lỗi U6-33 — Sharp MX6580N
Code:
Tất cả lỗi (328)
A0-01
A0-02
A0-04
A0-10
A0-15
A0-17
A0-18
A0-19
A0-20
A0-21
A0-22
C1-01
C1-03
C1-05
C1-07
C1-10
C1-14
C1-40
C4-00
C4-01
C4-20
C4-21
C4-25
C4-30
C4-30
C4-31
C4-31
C4-35
E6-10
E6-11
E6-14
E7-01
E7-03
E7-04
E7-10
E7-11
E7-14
E7-20
E7-21
E7-22
E7-23
E7-24
E7-25
E7-26
E7-27
E7-28
E7-29
E7-42
E7-46
E7-47
E7-48
E7-49
E7-50
E7-55
E7-60
E7-61
E7-62
E7-80
E7-89
E7-90
E7-91
E7-92
E7-93
E7-94
E7-96
E7-A0
E7-A1
E7-A2
E7-A3
E7-A7
E7-C0
E7-C1
EE-EC
EE-EL
EE-EU
F0-03
F0-08
F0-10
F0-11
F0-14
F0-15
F0-18
F0-19
F0-20
F0-23
F0-25
F0-28
F0-29
F0-30
F0-31
F0-32
F0-33
F0-34
F0-37
F0-40
F0-41
F0-42
F0-43
F0-44
F0-45
F0-46
F0-47
F0-48
F0-49
F0-51
F0-52
F0-53
F0-54
F0-55
F0-56
F0-70
F0-71
F0-72
F0-73
F0-74
F0-75
F0-76
F0-77
F0-80
F0-81
F0-82
F0-83
F0-84
F0-86
F1-00
F1-03
F1-08
F1-10
F1-15
F1-19
F1-21
F1-22
F1-23
F1-30
F1-31
F1-32
F1-33
F1-34
F1-37
F1-38
F1-41
F1-42
F1-43
F1-44
F1-45
F1-46
F1-50
F1-51
F1-52
F1-60
F1-64
F1-65
F1-66
F1-67
F1-90
F1-96
F1-97
F1-98
F1-99
F2-22
F2-23
F2-24
F2-25
F2-39
F2-40
F2-41
F2-42
F2-43
F2-45
F2-49
F2-50
F2-51
F2-52
F2-53
F2-58
F2-64
F2-65
F2-66
F2-67
F2-70
F2-71
F2-72
F2-73
F2-74
F2-75
F2-76
F2-77
F2-78
F2-A0
F2-A1
F2-A2
F2-A3
F3-12
F3-22
F3-32
F3-42
F6-00
F6-01
F6-02
F6-04
F6-21
F6-30
F6-97
F6-98
F9-00
H2-00
H2-01
H2-02
H2-03
H2-04
H2-05
H2-06
H2-07
H3-00
H3-01
H3-02
H4-00
H4-01
H4-02
H4-30
H4-31
H4-32
H5-01
H7-10
H7-11
L1-00
L3-00
L4-02
L4-03
L4-06
L4-07
L4-08
L4-16
L4-17
L4-18
L4-19
L4-20
L4-30
L4-31
L4-32
L4-33
L4-34
L4-35
L4-36
L4-38
L4-39
L4-40
L4-41
L4-42
L4-43
L4-44
L4-48
L4-49
L4-56
L4-57
L4-58
L4-60
L4-61
L6-10
L8-01
L8-02
L8-11
L8-12
L8-20
PC--
U1-01
U2-00
U2-05
U2-11
U2-30
U2-40
U2-41
U2-42
U2-50
U2-60
U2-70
U2-80
U2-81
U2-90
U2-91
U5-00
U5-16
U5-20
U5-30
U5-31
U6-09
U6-20
U6-21
U6-22
U6-23
U6-24
U6-29
U6-33
U6-34
U6-39
U6-51
U6-54
U6-63
U6-68
U6-69
U6-80
U6-81
U6-82
U6-83
U6-84
U7-50
U7-51
U9-01
UC-02
UC-12
UC-20
UC-30
UE-10
UE-11
UE-12
UE-13
UE-14
UE-15
UE-16
UE-17
UE-20
UE-21
UE-22
UE-23
UE-24
UE-25
UE-26
UE-27
Code:
U6-33
Description: LCT2 reverse winding detection trouble. It is detected that the wire of the tray is reversely wound.
Causes: Reverse winding detection SW ON The wire is reversely wound. Reverse winding detection SW trouble Connection trouble of the connector and the harness A3 2-stage LCT control PWB trouble
Remedy: Check the wire. Replace the reverse winding SW. Check connection of the connector and the harness. Replace the A3 2-stage LCT control PWB.