Code: 03-200 ... 03-250
Description: MSOK Faults
Causes: These are the faults displayed when the machine encounters MSOK problems. The faults are listed in code order, together with any recommended actions.
Remedy: 03-200 System Fault - IOT Serial Number Invalid, Call for Assistance The IOT serial number is invalid. Perform the following: 1. Contact Field Engineering for assistance. 03-210 System Fault - MSOK Invalid - Call for Assistance (MMSOK) The MSOK serial number is invalid. Perform the following: 1. Contact Field Engineering for assistance. 03-220 System Fault - MSOK Invalid - Call for Assistance MMSOK Bit The MSOK has the manufacturing SOK serial number but not the MMSOK part. Perform the following: 1. Contact Field Engineering for assistance. 03-230 System Fault - MSOK Page Count Exceeded The IOT has attempted to print more pages that the MMSOK can print. Perform the following: 1. Remove the MMSOK, then install the MSOK. 2. Contact Field Engineering for further assistance. 03-240 System Fault - Invalid Machine or MSOK SN The MSOK SN is empty. Perform the following: 1. Contact Field Engineering for assistance. 03-250 MSOK Missing The MSOK is not installed. Perform the following: 1. Check that the MSOK is connected to the main PWB.