Code: J7-1, J7-2
Description: Drum Cartridge Failure - J7-n Comm/NVRAM/Type Error The Drum Cartridge CRUM failed to communicate with the Engine Control Board. • Drum Cartridge Failure - J7-1 DRUM Comm Error • Drum Cartridge Failure - J7-2 DRUM NVRAM Error
Causes: • Drum Cartridge • Drum Cartridge CRUM PWB • Engine Control Board
Remedy: 1 Check the Drum Cartridge installation. Was the Drum Cartridge replaced? Go to Step 2. Replace the Drum Cartridge. If the error persists, go to Step 2. 2 Check the Drum Cartridge CRUM PWB. Is the Drum Cartridge CRUM PWB installed correctly? Go to Step 3. Correct the installation. 3 Check the Drum Cartridge CRUM PWB connection. Are P126 and P/J419 connected? Go to Step 4. Connect P/126 and P/J419. 4 Check continuity between the Drum Cartridge CRUM PWB and Engine Control Board. 1. Disconnect P/126 and P/J419. 2. Check for continuity at the following: • P126-6 <=> P/J419-1 • P126-5 <=> P/J419-2 • P126-4 <=> P/J419-3 • P126-3 <=> P/J419-4 • P126-2 <=> P/J419-5 Are these conductive? Go to Step 5. Repair the wiring. 5 Check +5 V to Drum Cartridge CRUM PWB. Is there +5 V across P126-6 (+) <=> ground? Replace the Drum Cartridge CRUM PWB. Replace the Engine Control Board.