Code: U4-1
Description: Fuser Failure - U4-1 On Time NOTE: Following display of this error, leave power applied for 7 minutes, then cycle printer power. If the error reoccurs, proceed with troubleshooting procedure. The Fuser failed to reach temperature within the warm-up period. Possible faults are: • During the Warm-Up period, the Control Thermistor does not detect the Ready temperature even when the specified time has passed. • During the Standby period, the Control Thermistor does not detect the required temperature even when the specified time has passed. • During idling after power-on, the Control Thermistor does not detect the idling stop temperature even after the specified time has passed. • During print, the Control Thermistor does not detect the required temperature even when the specified time has passed.
Causes: • Fuser • LVPS
Remedy: 1 Check the Fuser for a paper jam. Open Door A. Is there a paper jam in the Fuser? Remove the paper. Go to Step 2. 2 Check the Fuser installation. Is the Fuser installed properly? Go to Step 3. Correct the installation. If the error persists, replace the Fuser and go to Step 10. 3 Check continuity on the junction connector. WARNING Allow the Fuser to cool. Remove the Fuser. Is there continuity on the pins? Go to Step 4. Replace the Fuser. 4 Check Fuser resistance. Is the resistance across P/J600-1 and P/ J600-11 less than or equal to 100 ohms? Go to Step 5. Replace the Fuser. 5 Check Fuser resistance. Is the resistance across P/J600-4 and P/ J600-11 less than or equal to 100 ohm? Go to Step 6. Replace the Fuser. 6 Check Fuser resistance. Is the resistance across P/J600-7 and P/ J600-11 less than or equal to 100 ohm? Go to Step 7. Replace the Fuser. 7 Check Fuser resistance. Is the resistance across P/J131-1 and P/ J131-2 more than or equal to 3 k-ohm? Go to Step 8. Replace the Fuser. 8 Check Fuser resistance. Is the resistance between P/J132-1 and P/ J132-2 greater than or equal to 3 k-ohm? Go to Step 9. Replace the Fuser. 9 Check Fuser resistance. Is the resistance across P/J133-1 and P/ J133-2 greater than or equal to 3 k-ohm? Go to Step 10. Replace the Fuser. 10 Check Fuser connection. Is P/J6 connected? Go to Step 11. Connect P/J6. 11 Check continuity between the Fuser and LVPS. Is there continuity on each wire between P/ J600 <=> P/J6? Go to Step 12. Repair the wiring. 12 Check for +5 V to the Fuser. Is there +5 V between these pins? • P/J6-1 <=> P6-2 • P/J6-1 <=> P6-3 • P/J6-1 <=> P6-4 Replace the Fuser. Replace the LVPS. 13 Check the LVPS and the Engine Control Board connection. Are P/J401 and P/J525 connected? Replace the Engine Control Board. Connect P/J401 and P/J525.