Mã lỗi 042-313 — Xerox Phaser 6140

Code: 042-313

Description: Fan Motor 042-313 The Fan has failed.
Causes: • MCU HAN Harness, PL5.1.28 • Fan, PL8.1.1 • LVPS, PL8.2.1 • MCU Board, PL8.2.13 • Fan Board, PL8.2.20 • LVPS Harness, PL9.1.3
Remedy: 1 Test the Fan Motor: Engine Diag > Motor Test > Fan High. Does the Fan rotate? Replace the MCU Board. Go to Step 2. 2 Check P/J510 on the Fan Board. Is the connection secure? Go to step 3 Secure the connector. 3 Check P/J520 on the Fan Board and P/J503 on the LVPS. Are the connections secure? Go to step 4. Secure the connectors. 4 Check P/J530 on the Fan Board and P/J30 on the MCU Board. Are the connections secure? Go to step 5. Secure the connectors. 5 Check P/J501 on the LVPS and P/J14 on the MCU Board. Are the connections secure? Go to step 6. Secure the connectors. 6 Check the LVPS2 Harness continuity. Disconnect P/J501 from the LVPS and P/J14 from the MCU Board. Is the harness damaged? Repair the harness. Go to step 7. 7 Check the MCU HAN harness continuity. Disconnect P/J530 from the Fan Board and P/J30 from the MCU Board. Is the harness damaged? Repair the harness. Go to step 8. 8 Check for +24 V at J503 on the LVPS. Is +24 V available at J503-1 <=> ground when the Interlock Switch is closed? Replace the Fan. Go to step 9. 9 Replace the Fan Board. Does the error persist? Go to step 10. Complete. 10 Replace the LVPS. Does the error persist? Replace the MCU Board. Complete.

← Xem tất cả mã lỗi Xerox Phaser 6140

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie