Code: 042-325-01
Description: Sub Motor Error The Sub Motor has failed.
Causes: • MCU Board, PL9.1.20 • Right Side Harness, PL10.1.15 • Main Drive, PL8.1.2
Remedy: 1 1. Check the detailed error code (press the Up and Down buttons simultaneously). 2. Does code g01h display on the Control Panel? Go to step 2. 2 1. Check the Print Cartridges for correct installation. 2. Are the Print Cartridges correctly installed? Go to step 4. Reseat the Print Cartridges. Go to step 3. 3 Does the error still occur? Go to step 4. Complete. 4 1. Check the wiring harness connectors P/J22 and P/J221 between the MCU Board and the Main Drive Assembly. 2. Are the connectors securely connected? Go to step 5. Reconnect the connectors. Go to step 5. 5 1. Perform the Sub Motor test: Service Mode > Engine Diag > Motor Test > Sub Motor. During the test, close the Front Cover. 2. Does the Motor operate properly? Replace the MCU Board. Go to step 6. 6 1. Check the Main Drive Assembly for correct installation. 2. Is the Main Drive Assembly correctly installed? Go to step 7. Reseat the Main Drive Assembly. Go to step 8. 7 Does the error still occur? Go to step 8. Complete. 8 Check the Right Side Harness for continuity. 1. Disconnect P/J22 from the MCU Board and P/J221 from the Main Drive Assembly. 2. Check continuity between P/J22 <=> P/J221. Go to step 9. Replace the Right Side Harness. 9 Check the Main Drive Assembly signal. 1. Disconnect P/J22 from the MCU Board. 2. Are there +24 V across ground <=> J22-A2/J22-A4 pin when the Interlock Switch is activated? Replace the Main Drive Assembly. Replace the MCU Board.