Mã lỗi 16A — Xerox WorkCentre 3655

Code: 16A

Description: Network Error Entry Use this RAP when the customer reports network failures. e.g. Cannot connect to the scan server when using FTP or SMB protocols, or when a folder on the scan server cannot be opened. NOTE: The fault message appears on the confirmation report. The report may take several minutes to print after scanning the document.
Remedy: NOTE: If it is possible to log into CWIS by entering the printer’s IP address, then the network controller on the IP Board is good. Perform the following: 1. Check that the printer date and time are correctly set. 2. Print a Configuration page. 3. Check that confirmation report printing is enabled. If necessary, ask the customer to enable printing of the confirmation report. 4. Ensure that the printer is configured for scan to file: a. Check the back of the configuration report under the heading Workflow Scanning. b. If a IP address or name is not listed next to Alt1 Repository Protocol, ask the customer to configure the machine before continuing. 5. Go to the relevant procedure: • 16B FTP or SMB Unable to Connect to Remote Server RAP. • 16C Remote Directory Lock Failed RAP.

← Xem tất cả mã lỗi Xerox WorkCentre 3655