Description: IOT NVM Error 41-340-00 IOT NVM-Verify Data Read error 41-342-00 F/W Exception Handling Error 41-400-00 IOT NVM-Read NVM failure version 41-402-00 IOT NVM-Read the data write copy failed area at three locations 41-404-00 IOT NVM-Ack-time error 1byte Read 41-406-00 IOT NVM-Ack-time error Continuous Read 41-408-00 IOT NVM-Write on the device can not start Busy 41-410-00 IOT NVM-Can not Write (Verify error) 41-412-00 IOT NVM-Write process is completed without 41-414-00 IOT NVM-Write retry processing over NOTE: Status codes 03-561 and 04-563 are raised with this fault code.
Remedy: Do not replace the MCU and IP Boards at the same time. Replace or check the IP Board first, then cycle system power before replacing the MCU Board. Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Check the wiring and connections between the MCU and IP Boards. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Install new components as necessary: • MCU Board • IP Board