Description: IOT I/F Error 41-301-00 I/F Ack Unreceived High 41-302-00 I/F Ack Unreceived Low 41-303-00 I/F Received Buffer Overflow 41-304-00 I/F Send Buffer High Overflow 41-305-00 I/F Send Buffer Low Overflow NOTE: Status codes 03-561 and 04-566 are raised with this fault code
Remedy: Do not replace the MCU and IP Boards at the same time. Replace or check the IP Board first, then cycle system power before replacing the MCU Board. Simultaneous replacement of IP and MCU Boards will make the printer inoperable. Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Check the wiring and connections between the MCU and IP Boards. The wiring is good. Y↓N→Re-seat loose connectors or install new components as necessary: • MCU Board • IP Board Go to SCP 6 and complete the Final Actions