Description: Exit On/Off Jam 77-103-00 Exit Off Jam 77-104-00 Exit Off Early Jam 77-106-00 Exit On Jam NOTE: Status code 07-5?? is raised with this fault code.
Remedy: Check the Nudger, Feed, and Separator Rollers for excessive wear or contamination. The rollers are undamaged and clean. Y↓N→Clean or replace the rollers. Use dC330 code 071-103 to test the Exit Sensor. The sensor signal changes. Y↓N→Replace the Exit Sensor. Use dC330 code 071-102 to test the Registration Sensor. The sensor signal changes. Y↓N→Replace the Registration Sensor. Use dC330 code 071-007 to test the Exit Clutch. The clutch activates. Y↓N→Replace the Exit Clutch. Use dC330 code 071-006 to test the Registration Clutch. The clutch activates. Y↓N→Replace the Registration Clutch. Use dC330 code 071-001 to test the Main Drive Assembly. The motor rotates. Y↓N→Replace the Main Drive Assembly . lnstall new components as necessary: 1. Exit Chute Assembly 2. MCU Board