Code: E3-6
Description: Exit SNR JAM. Fuser Exit Sensor ON is detected during standby.
Remedy: I/O Diagnostic Codes [10-23] Fuser Exit Sensor
Check Items: • Fuser Exit Sensor dirty and Sensor Actuator deformed or damaged • Foreign matter, burrs, or paper in the paper path • Check that the following wires are connected securely with good electrical contact. If there is no problem, replace the Fuser Exit Sensor (PL 6.2). – Wire between Fuser Exit Sensor J153-3 ( P/J153) and LVPS J505-1 ( P/J505) – Wire between Fuser Exit Sensor J153-2 and LVPS J505-2 – Wire between Fuser Exit Sensor J153-1 and LVPS J505-3 • Replace the AIOC PWB (PL 8.1) .
Check Items: • Fuser Exit Sensor dirty and Sensor Actuator deformed or damaged • Foreign matter, burrs, or paper in the paper path • Check that the following wires are connected securely with good electrical contact. If there is no problem, replace the Fuser Exit Sensor (PL 6.2). – Wire between Fuser Exit Sensor J153-3 ( P/J153) and LVPS J505-1 ( P/J505) – Wire between Fuser Exit Sensor J153-2 and LVPS J505-2 – Wire between Fuser Exit Sensor J153-1 and LVPS J505-3 • Replace the AIOC PWB (PL 8.1) .