Code: E5-2
Description: IOT Front Cover open. The Front Cover is open.
Remedy: I/O Diagnostic Codes [01-12] Front Cover Interlock Switch
Check Items: • Check that the Front Cover closes correctly. • Check that the Front Cover Interlock Switch is correctly installed and that the electrical connection is good. • Check that the following wires are connected securely with good electrical contact. If there is no problem, replace the Front Cover Interlock Switch (PL 8.2). – Wire between Front Cover Interlock Switch FS153 ( FS153) and LVPS J506-2 ( P/J506) – Wire between Front Cover Interlock Switch FS154 ( FS154) and LVPS J506-1 • Replace the LVPS (PL 8.1) and the AIOC PWB (PL 8.1) in that order.
Check Items: • Check that the Front Cover closes correctly. • Check that the Front Cover Interlock Switch is correctly installed and that the electrical connection is good. • Check that the following wires are connected securely with good electrical contact. If there is no problem, replace the Front Cover Interlock Switch (PL 8.2). – Wire between Front Cover Interlock Switch FS153 ( FS153) and LVPS J506-2 ( P/J506) – Wire between Front Cover Interlock Switch FS154 ( FS154) and LVPS J506-1 • Replace the LVPS (PL 8.1) and the AIOC PWB (PL 8.1) in that order.