Mã lỗi U1-1 — Xerox WorkCentre 5016

Code: U1-1

Description: Main Motor Rotation Error. 500 ms after the IOT Motor starts, the IOT Motor Lock signal is Low.
Remedy: Close the Left Hand Cover and the Front Cover. Execute diagnostics [04--01 Main Motor On]. The IOT Motor can be heard rotating. Y↓N→Check P/J504 and P/J201. Both P/J504 and P/J201 are connected securely. Y↓N→Connect P/J504 and P/J201 securely. Measure the voltage between LVPS PWB P504-1 ( P/J504) (+) and GND (-). The voltage is approximately +24VDC. Y↓N→Replace the LVPS (PL 8.1). Check the wire between J504-3 ( P/J504) and J201-3 ( P/J201). The wire is not shorted or open. Y↓N→Repair the wire. Replace the IOT Motor (PL 1.1) and the AIOC PWB (PL 8.1) in that order. Check the installation of the IOT Motor (PL 1.1 ) . The IOT Motor is installed properly. Y↓N→Install the IOT Motor (PL 1.1 ) properly. Turn the rotor of the IOT Motor (PL 1.1 ) counterclockwise by hand. It rotates smoothly, without any abnormal load. Y↓N→Check for any foreign substances that obstruct the drive and for any incorrectly installed parts. There are foreign substances or incorrectly installed parts. Y↓N→Replace the IOT Motor (PL 1.1) . Remove any foreign substances and fix any installation errors. Check the wire between J504-3 ( P/J504) and J201-3 ( P/J201). The wire is not shorted or open. Y↓N→Repair the wire. Replace the IOT Motor (PL 1.1) and the AIOC PWB (PL 8.1) in that order.

← Xem tất cả mã lỗi Xerox WorkCentre 5016

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie