Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi U2-1 — Xerox WorkCentre 5016

Code: U2-1

Description: Carriage Module Fail. A carriage fault was detected.
Remedy: Execute diagnostics [05-22 Move scanner to home position] and [05-23 Move scanner to maintenance position]. The carriage moves. Y↓N→Check each IIT Carriage connector. Each connector is connected securely. Y↓N→Connect each connector securely. Check for foreign substances and deformed parts in the carriage. None is found. Y↓N→Remove the foreign substances and repair the deformed parts. Replace the IIT Carriage (PL 10.3) . Execute diagnostics [05-23 Move scanner to maintenance position]. When the IIT Carriage has moved to the leftmost position, press the [Stop] button to put the Carriage Sensor into the blocked state. Execute diagnostics [5-11 Home Sensor], and "H" is displayed. Y↓N→Check each IIT Carriage and Carriage Sensor connector. Each connector is connected securely. Y↓N→Connect each connector securely. Replace the Carriage Sensor (PL 10.6) and the IIT Carriage (PL 10.3) in that order. Check the Carriage Sensor (PL 10.6 ). The Carriage Sensor is installed properly. Y↓N→Install the Carriage Sensor (PL 10.6) properly. Replace the IIT Carriage (PL 10.3) .

← Xem tất cả mã lỗi Xerox WorkCentre 5016

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie