Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi U3-5 — Xerox WorkCentre 5016

Code: U3-5

Description: Laser Power Or ROS Motor Fail. The ROS Motor does not turn, or the laser output is not normal.
Remedy: Execute diagnostics [6-15 ROS Motor ON]. The ROS Motor can be heard rotating. Y↓N→Measure the voltage between the AIOC PWB P403-7 ( P/J403) (+) and GND (-). The voltage is approximately +24VDC. Y↓N→Replace the AIOC PWB (PL 8.1) and the LVPS (PL 8.1) in that order. Replace the ROS (PL 3.1) and the AIOC PWB (PL 8.1) in that order. Measure the voltage between the AIOC PWB P403-1 ( P/J403) (+) and GND (-). The voltage is approximately +5VDC. Y↓N→Replace the AIOC PWB (PL 8.1) . Check the AIOC PWB P/J403 ( P/J403), LD PWB P/J140 ( P/J140), and P/J130 ( P/J130) connectors. The P/J403, P/J140, and P/J130 connectors are connected securely. Y↓N→Connect the AIOC PWB P/J403 ( P/J403), LD PWB P/J140 ( P/J140), and P/J130 ( P/ J130) connectors securely. Check the wires between J403 ( P/J403) and J140 ( P/J140) and between J403 and J130 ( P/ J130) The wires are not shorted or open. Y↓N→Repair the wire(s). Replace the ROS (PL 3.1) and the AIOC PWB (PL 8.1) in that order.