Mã lỗi U4-1 — Xerox WorkCentre 5016

Code: U4-1

Description: Fuser On Time Fail. • The lamp did not turn OFF within the specified time after turning ON. • Or, Warm Up was not completed within the specified time after power ON.
Remedy: When U4-1 occurs, [NVM 50-20 FSR Reset FuserOverTemp] becomes "3." Run [NVM 50-20 FSR Reset FuserOverTemp] using "0" to reset it. Check to see if there is paper in the Fuser. The Fuser is normal and there is no paper in it. Y↓N→Remove the paper. Check the condition of the Fuser. The Fuser is installed properly. Y↓N→Install the Fuser properly. Remove the Fuser. Check the conductivity between the Thermostat contacts. The contacts are conductive. Y↓N→Replace the Fuser (PL 5.1) . Check the Heater Rod for an open circuit. There is no open circuit between J600-1 ( P/ J600) and J600-2. Y↓N→Replace the Fuser (PL 5.1) . Check the resistance of the Thermistor. There is no open circuit between J601-1 ( P/J601) and J601-2, and the resistance is a minimum of 228k ohms (cold). Y↓N→Replace the Fuser (PL 5.1) . Immediately after Main Switch ON, the voltage between J3-3 ( P/J3) (ACH) and J3-1 (ACN) is approximately 200VAC. Y↓N→Replace the LVPS (PL 8.1) . Check the wire between J408 ( P/J408) and P601 ( P/J601). The wire between J408 and P601 is not shorted or open. Y↓N→Repair the wire. Check the wire between J3 ( P/J3) and P600 ( P/J600). The wire between J3 and P600 is not shorted or open. Y↓N→Repair the wire. Replace the Fuser (PL 5.1) , the LVPS (PL 8.1) , and the AIOC PWB (PL 8.1) in that order.

← Xem tất cả mã lỗi Xerox WorkCentre 5016

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie