Description: NOHAD Fan Defect NOHAD Fan failure was detected. When the NOHAD Fan Fail signal indicating an abnormality of the Fan was monitored at the specified time interval, it was found to have failed the specified number of times or higher in a row.
Remedy: 1. Check the NOHAD Fan (Output Check [042-002]) for operation failure. (PL 4.1) 2. Check the NOHAD Fan for foreign substances. 3. If no problem is found, replace the ESS/MCU PWB. (PL 18.1)