Description: N-Up NG Out Of Range/ AMS NG Out Of Range [N-Up NG Out Of Range] During 2-Up or 4-Up, the reduce/enlarge ration was not within the range of 25 to 400%. [AMS NG Out Of Range] During AMS (Auto Magnification Selection), the reduce/enlarge ration was not within the range of 25 to 400%
Remedy: Press [Stop] on the UI Panel and change the settings.
Description: IPS Overrun The IPS processing has overtook the Scan processing
Remedy: This might be avoided by setting the R/E ratio to 99% or 101%. If this occurs frequently, obtain the document from the User and contact the Support Department for assistance.
Description: Not-Supported Doc Size During DADF Scan of a Copy Job, an unsupported document size was detected.
Remedy: 1. Press [Stop] on the UI Panel. 2. Check the setting of the document size group. 3. Check whether the document size is a supported size. 4. If the document size is a supported size, the DADF might have malfunctioned. Refer to following FIP to check the DADF. • 005-196 (Size Mismatch Jam on No Mix-size) • 005-948 (SS-Size Mismatch Jam on No Mix-size)
Description: APS NG Out Of Range During Copy Job, when APS is selected, the image size obtained from document size x reduce/enlarge ratio was detected to be larger than the largest Standard Paper Size.
Remedy: Press [Stop] on the UI Panel and change the settings.
Description: During Copy Job, the EPC memory is filled up.
Remedy: Print out all the images that had been successfully scanned by the DADF so far and then perform the copy again for the documents (images) that were unable to be scanned.
Description: Auto Rotation NG Out Of Range During Copy Job, the following conditions were met. • Rotation is required. • The length of the image obtained by document x reduce/enlarge ratio is longer than 297 mm.
Remedy: Press [Stop] on the UI Panel and change the reduce/enlarge ratio.
Description: HVPS Communication Error Communication failure between the ESS/MCU PWB and the HVPS was detected.
Remedy: 1. Turn the power OFF and ON. 2. Turn OFF the power and check the connection between the HVPS J500 and the ESS/ MCU PWB J402 for open circuit, short circuit, and poor contact. 3. If no problem is found, replace the following parts in sequence: • HVPS (PL 18.1) • ESS/MCU PWB (PL 18.1)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.