Mã lỗi 077-106 — Xerox WorkCentre 5021

Code: 077-106

Description: Fusing Unit Exit Sensor On Jam The Fusing Unit Exit Sensor did not turn ON within the specified time after the Regi Clutch On.
Remedy: Check the following: • The Fusing Unit Exit Sensor (Input Check [071-106]) for operation failure. (PL 7.1) • The Main Drive Motor (Output Check [042-001]) for operation failure. (PL 3.1) • The Regi Clutch (Output Check [071-001]) for operation failure. (PL 15.1) • The Fusing Unit Exit Chute for improper installation and deformation. • The Transfer Unit for a decrease in the transportation force. • The Drive Gear for wear and damage. • The Heat Roll for wound up, stuck paper. • A paper transportation failure due to foreign substances on the paper path. • Usage of out of spec paper. If no problems are found, replace the ESS/MCU PWB. (PL 18.1)